率/顯示繼電器輸出流量變送器 fp90系列 和復位累加器 可擴展的輸出 繼電器選項 安裝通用性 模擬功能 2×16點陣字符液晶 耐化學腐蝕外殼和自愈窗口 大按鈕 清楚標明終端標簽應用 流量控制和監(jiān)測 過濾或軟化器再生 污水綜合化 泵保護 給水泵脈沖 水的分布 Leak Detection The FP90 Series Flow Transmitter is an advanced solution that converts the signal from many flow sensors into a 4 to 20 mA signal for long distance transmission. Configuration flexibility is maximized with two optional relays for process control two packaging options for integral/pipe mount or panel installation and scalability for virtually any flow range or engineering unit. State-of-the-art electronic design ensures long-term reliability signal stability and simple user setup and operation. The FP90 can be integrally mounted to FP8500 series paddlewheel sensors utilizing an mounting kit. The FP90 can be remotely used with the OMEGA ? FP-5100 FP-5200 FP-5300 FP-5060 FP-2541 FP-5600 FP-3-1500 or FP-6000 flow sensors and a FP90UM mounting kit. The FP90-XP units are designed to be panel mounted. The three front keys control all programming and scaling of the FP90-there are not pots to tweak or internal adjustments to make. Simply enter the K-factor and the FP90 displays rate with field-adjustable decimal point mA output value total (field selectable for resettable or non-resettable operation) and the date of the last reprogramming. The 8-digit alphanumeric LCD shows every program step in clear language allowing display in any engineering units and timebase in seconds minutes hours or days. A special pushbutton sequence permits entry into the programming thus providing security against unauthorized reprogramming. SPECIFICATIONS Compatibility: Flow Sensors with frequency outputs Accuracy: ±0.5% of reading @ 25°C Enclosure Rating: NEMA 4X (IP65) front Case: PBT Window: Polyurethane coated polycarbonate Keypad: Sealed 4-key silicone rubber Weight: Approx. 325 g (12 oz) Display: Alphanumeric 2 x 16 LCD Update Rate: 1 second Contrast: User selected 5 levels Environmental Operating Temperature: -10 to 70°C (14 to 158°F) Storage Temperature: -15 to 80°C (5 to 176°F) Relative Humidity: 0 to 95% non-condensing Electrical Sensor Input: Range: 0.5 to 1500 Hz Sensor Power: 2-Wire: 1.5 mA @ 5 Vdc ±1% 3 or 4 Wire: 20 mA @ 5 Vdc ±1% Optically isolated from current loop; short circuit protected Current Output: 4 to 20 mA isolated fully adjustable and reversible Power: 12 to 24 Vdc ±10% regulated Max Loop Impedance: 50 Ω max @ 12 V 325 Ω max @ 18 V 600 &Omega max @ 24 V Update Rate: 100 ms Accuracy: ±0.03 mA Relay Output: Mechanical SPDT Contacts: Hi Lo Pulse Off Maximum Voltage Rating: 5 A @ 30 Vdc 5 A @ 250 Vac resistive load Hysteresis: User adjustable; max 300 pulses/min Open-Collector Output: Hi Lo Pulse Off Open-collector optically isolated 50 mA max sink 30 Vdc max pull-up voltage. Max 300 pulses/min For complete product specifications see the Related Links section at the bottom of this page. ?
產(chǎn)品型號/產(chǎn)品描述 Flow Transmitters FP90-1 Field mount transmitter with 4-20mA and open collector outputs FP90-2 Field mount transmitter with 4-20mA output and 2 relays FP90-3 Field mount for 1 or 2 inputs with 4-20mA output for input 1 2 or differential FP90-1P Panel mount transmitter with 4-20mA and open collector outputs FP90-2P Panel mount transmitter with 4-20mA output and 2 relays FP90-3P Panel mount transmitter for 1 or 2 inputs with 4-20mA output for input 1 2 or differential Flow Sensors for Integral Mounting (Requires FP90IM) FP8501 1/2 " to 4" pipe polypropylene body/titanium shaft Min Flow 1 FPS FP8502 5" to 8" pipe polypropylene body/titanium shaft Min Flow 1 FPS FP8503 1/2 " to 4" pipe PVDF body/Hastelloy C shaft Min Flow 1 FPS Low Flow Sensors (0.3 fps min) for Integral Mounting (Requires FP90IM) FP8501A 1/2 " to 4" pipe polypropylene body/titanium shaft Min Flow 0.3 FPS FP8502A 5" to 8" pipe polypropylene body/titanium shaft Min Flow 0.3 FPS FP8503A 1/2 " to 4" pipe PVDF body/Hastelloy C shaft Min Flow 0.3 FPS Remote Mount Paddlewheel Sensors FP-5300 1/2 " to 4" pipe polypropylene body/titanium shaft Min Flow 1 FPS FP-5600 1/2 " to 4" pipe polypropylene body/titanium shaft Min Flow 0.3 FPS Accessories FP90IM Integral mounting kit for mounting on top of FP85XX sensors FP90UM Universal mounting kit for remote wall or pipe mount FP90-4X NEMA 4X cover (panel mount) FP90RC RC filter (for relay use) U24Y175 24 Vdc1 175 mA Power Supply Popular Sensor Installation fittings FP-5307M 3/4" molded PVC FP-5307CU 3/4" Copper FP-5320M 2" molded PVC FP-5320GI 2" NPT Galvanized Iron FP-5340CS 4" Carbon Steel Weldolet
注釋: * Field mount transmitters require FP90IM internal mounting kit for FP8500 or FP8500A sensor or FP90UM for all other compatible sensors. Fittings are also required see FP series fittings. FP90 comes complete with operator&s manual. FP90-XP comes complete with mounting bracket panel gasket and operator&s manual.
FP-5300流量變送器 美國omega
率/顯示繼電器輸出流量變送器
fp90系列
和復位累加器
可擴展的輸出
繼電器選項
安裝通用性
模擬功能
2×16點陣字符液晶
耐化學腐蝕外殼和自愈窗口
大按鈕
清楚標明終端標簽應用
流量控制和監(jiān)測
過濾或軟化器再生
污水綜合化
泵保護
給水泵脈沖
水的分布
Leak Detection
The FP90 Series Flow Transmitter is an advanced solution that converts the signal from many flow sensors into a 4 to 20 mA signal for long distance transmission. Configuration flexibility is maximized with two optional relays for process control two packaging options for integral/pipe mount or panel installation and scalability for virtually any flow range or engineering unit. State-of-the-art electronic design ensures long-term reliability signal stability and simple user setup and operation. The FP90 can be integrally mounted to FP8500 series paddlewheel sensors utilizing an mounting kit. The FP90 can be remotely used with the OMEGA ? FP-5100 FP-5200 FP-5300 FP-5060 FP-2541 FP-5600 FP-3-1500 or FP-6000 flow sensors and a FP90UM mounting kit. The FP90-XP units are designed to be panel mounted. The three front keys control all programming and scaling of the FP90-there are not pots to tweak or internal adjustments to make. Simply enter the K-factor and the FP90 displays rate with field-adjustable decimal point mA output value total (field selectable for resettable or non-resettable operation) and the date of the last reprogramming. The 8-digit alphanumeric LCD shows every program step in clear language allowing display in any engineering units and timebase in seconds minutes hours or days. A special pushbutton sequence permits entry into the programming thus providing security against unauthorized reprogramming.
SPECIFICATIONS
Compatibility: Flow Sensors with frequency outputs
Accuracy: ±0.5% of reading @ 25°C
Enclosure
Rating: NEMA 4X (IP65) front
Case: PBT
Window: Polyurethane coated polycarbonate
Keypad: Sealed 4-key silicone rubber
Weight: Approx. 325 g (12 oz)
Display: Alphanumeric 2 x 16 LCD
Update Rate: 1 second
Contrast: User selected 5 levels
Environmental
Operating Temperature: -10 to 70°C (14 to 158°F)
Storage Temperature: -15 to 80°C (5 to 176°F)
Relative Humidity: 0 to 95% non-condensing
Electrical
Sensor Input:
Range: 0.5 to 1500 Hz
Sensor Power:
2-Wire: 1.5 mA @ 5 Vdc ±1%
3 or 4 Wire: 20 mA @ 5 Vdc ±1%
Optically isolated from current loop; short circuit protected
Current Output: 4 to 20 mA isolated fully adjustable and reversible
Power: 12 to 24 Vdc ±10% regulated
Max Loop Impedance: 50 Ω max @ 12 V 325 Ω max @ 18 V 600 &Omega max @ 24 V
Update Rate: 100 ms
Accuracy: ±0.03 mA
Relay Output: Mechanical SPDT
Contacts: Hi Lo Pulse Off
Maximum Voltage Rating: 5 A @ 30 Vdc 5 A @ 250 Vac resistive load
Hysteresis: User adjustable; max 300 pulses/min
Open-Collector Output: Hi Lo Pulse Off Open-collector optically isolated 50 mA max sink 30 Vdc max pull-up voltage. Max 300 pulses/min
For complete product specifications see the Related Links section at the bottom of this page.
?
產(chǎn)品型號/產(chǎn)品描述
Flow Transmitters
FP90-1 Field mount transmitter with 4-20mA and open collector outputs
FP90-2 Field mount transmitter with 4-20mA output and 2 relays
FP90-3 Field mount for 1 or 2 inputs with 4-20mA output for input 1 2 or differential
FP90-1P Panel mount transmitter with 4-20mA and open collector outputs
FP90-2P Panel mount transmitter with 4-20mA output and 2 relays
FP90-3P Panel mount transmitter for 1 or 2 inputs with 4-20mA output for input 1 2 or differential
Flow Sensors for Integral Mounting (Requires FP90IM)
FP8501 1/2 " to 4" pipe polypropylene body/titanium shaft Min Flow 1 FPS
FP8502 5" to 8" pipe polypropylene body/titanium shaft Min Flow 1 FPS
FP8503 1/2 " to 4" pipe PVDF body/Hastelloy C shaft Min Flow 1 FPS
Low Flow Sensors (0.3 fps min) for Integral Mounting (Requires FP90IM)
FP8501A 1/2 " to 4" pipe polypropylene body/titanium shaft Min Flow 0.3 FPS
FP8502A 5" to 8" pipe polypropylene body/titanium shaft Min Flow 0.3 FPS
FP8503A 1/2 " to 4" pipe PVDF body/Hastelloy C shaft Min Flow 0.3 FPS
Remote Mount Paddlewheel Sensors
FP-5300 1/2 " to 4" pipe polypropylene body/titanium shaft Min Flow 1 FPS
FP-5600 1/2 " to 4" pipe polypropylene body/titanium shaft Min Flow 0.3 FPS
Accessories
FP90IM Integral mounting kit for mounting on top of FP85XX sensors
FP90UM Universal mounting kit for remote wall or pipe mount
FP90-4X NEMA 4X cover (panel mount)
FP90RC RC filter (for relay use)
U24Y175 24 Vdc1 175 mA Power Supply
Popular Sensor Installation fittings
FP-5307M 3/4" molded PVC
FP-5307CU 3/4" Copper
FP-5320M 2" molded PVC
FP-5320GI 2" NPT Galvanized Iron
FP-5340CS 4" Carbon Steel Weldolet
注釋: * Field mount transmitters require FP90IM internal mounting kit for FP8500 or FP8500A sensor or FP90UM for all other compatible sensors.
Fittings are also required see FP series fittings.
FP90 comes complete with operator&s manual.
FP90-XP comes complete with mounting bracket panel gasket and operator&s manual.